{"id":7,"date":"2023-11-29T15:48:50","date_gmt":"2023-11-29T15:48:50","guid":{"rendered":"https:\/\/biochemistry.tamu.edu\/lbsd\/?page_id=7"},"modified":"2025-06-20T15:15:31","modified_gmt":"2025-06-20T15:15:31","slug":"7-2","status":"publish","type":"page","link":"https:\/\/biochemistry.tamu.edu\/lbsd\/","title":{"rendered":"Welcome to the Laboratory for Biomolecular Structure and Dynamics (LBSD)"},"content":{"rendered":"\n<div style=\"background-color:#500000;padding-left:7%;padding-right:7%;padding-bottom:5%;padding-top:15%\" class=\"wp-block-genesis-blocks-gb-container alignfull gb-block-container\"><div class=\"gb-container-inside\"><div class=\"gb-container-image-wrap\"><img decoding=\"async\" class=\"gb-container-image has-background-dim-100 has-background-dim\" src=\"http:\/\/biochemistry.tamu.edu\/lbsd\/wp-content\/uploads\/sites\/112\/2025\/06\/LBSD-Cover-1.png\" alt=\"\"\/><\/div><div class=\"gb-container-content\" style=\"max-width:1200px\">\n<h1 class=\"wp-block-heading has-background\" style=\"background:linear-gradient(135deg,rgb(255,255,255) 27%,rgba(155,81,224,0) 100%);font-size:48px\">Welcome to the Laboratory for Biomolecular Structure and Dynamics (LBSD)<\/h1>\n<\/div><\/div><\/div>\n\n\n\n<div style=\"height:2rem\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Adding a rare new capability, the Department of Biochemistry and Biophysics now houses a leading-edge 300 kV cryo-electron microscope. The award-winning Krios G4 provides unrivaled atomic resolution for single-particle and tomographic cryo-electron microscopy.<\/p>\n\n\n\n<p>The carefully renovated space for the instrument in the Biochemistry and Biophysics Building was built to minimize vibrations and other interferences. A continuous air exchange system allows for temperature control with minimum change in airflow. The room is also humidity-controlled to reduce ice contamination on the grids during handling.<\/p>\n\n\n\n<p>In September 2022, technical experts from Thermo-Fisher finished installing the instrument in collaboration with Gaya Yadav, Ph.D., technical director of the cryo-EM resource; Terry Lovingshimer, Operations Manager for Biochemistry and Biophysics; and&nbsp;<a href=\"https:\/\/bcbp.tamu.edu\/research\/faculty\/junjie-zhang\/\" target=\"_blank\" rel=\"noreferrer noopener\">Junjie Zhang<\/a>, Ph.D., Associate Professor and faculty director for the resource.<\/p>\n\n\n\n<p>The LBSB-cryoEM has already generated &gt;30 high-resolution structures after its inauguration in December 2022 with the 1.58A resolution for the ApoF and 1.90Angstrom for a membrane protein and 2.18A for a &lt;80kDa membrane protein in detergent.<\/p>\n\n\n\n<p><strong>Notable equipment<\/strong><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/biochemistry.tamu.edu\/lbsd\/wp-content\/uploads\/sites\/112\/2025\/06\/20221026_Cryo_EM_Lab_MM_098-2-1024x683.jpg\" alt=\"\" class=\"wp-image-102\" style=\"width:auto;height:250px\" srcset=\"https:\/\/biochemistry.tamu.edu\/lbsd\/wp-content\/uploads\/sites\/112\/2025\/06\/20221026_Cryo_EM_Lab_MM_098-2-1024x683.jpg 1024w, https:\/\/biochemistry.tamu.edu\/lbsd\/wp-content\/uploads\/sites\/112\/2025\/06\/20221026_Cryo_EM_Lab_MM_098-2-300x200.jpg 300w, https:\/\/biochemistry.tamu.edu\/lbsd\/wp-content\/uploads\/sites\/112\/2025\/06\/20221026_Cryo_EM_Lab_MM_098-2-768x512.jpg 768w, https:\/\/biochemistry.tamu.edu\/lbsd\/wp-content\/uploads\/sites\/112\/2025\/06\/20221026_Cryo_EM_Lab_MM_098-2-600x400.jpg 600w, https:\/\/biochemistry.tamu.edu\/lbsd\/wp-content\/uploads\/sites\/112\/2025\/06\/20221026_Cryo_EM_Lab_MM_098-2.jpg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li>Krios G4 Cryo-TEM, equipped with autoloader.<\/li>\n\n\n\n<li>Gatan K3&nbsp;direct electron detector Camera with BioContinuum post-column Imaging filter.<\/li>\n\n\n\n<li>Thermo&nbsp;Fisher Scientific phase plate.<\/li>\n\n\n\n<li>Ceta-D camera for low-dose diffraction data collection.<\/li>\n\n\n\n<li>Vitrobot&nbsp;Mark IV for sample vitrification.<\/li>\n\n\n\n<li>EasiGlow&nbsp;dual system (TedPella) for glow discharging the grids.<\/li>\n\n\n\n<li>GPU-accelerated workstation to process cryo-EM data.<\/li>\n<\/ul>\n\n\n\n<p>The laboratory is available to support research within the Texas A&amp;M University System and beyond (academic external and non-academic users).<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Adding a rare new capability, the Department of Biochemistry and Biophysics now houses a leading-edge 300 kV cryo-electron microscope. The award-winning Krios G4 provides unrivaled atomic resolution for single-particle and tomographic cryo-electron microscopy. The carefully renovated space for the instrument in the Biochemistry and Biophysics Building was built to minimize vibrations and other interferences. A [&hellip;]<\/p>\n","protected":false},"author":360,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_genesis_hide_title":true,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"class_list":{"0":"post-7","1":"page","2":"type-page","3":"status-publish","5":"entry"},"acf":[],"featured_image_src":null,"featured_image_src_square":null,"_links":{"self":[{"href":"https:\/\/biochemistry.tamu.edu\/lbsd\/wp-json\/wp\/v2\/pages\/7","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/biochemistry.tamu.edu\/lbsd\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/biochemistry.tamu.edu\/lbsd\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/biochemistry.tamu.edu\/lbsd\/wp-json\/wp\/v2\/users\/360"}],"replies":[{"embeddable":true,"href":"https:\/\/biochemistry.tamu.edu\/lbsd\/wp-json\/wp\/v2\/comments?post=7"}],"version-history":[{"count":0,"href":"https:\/\/biochemistry.tamu.edu\/lbsd\/wp-json\/wp\/v2\/pages\/7\/revisions"}],"wp:attachment":[{"href":"https:\/\/biochemistry.tamu.edu\/lbsd\/wp-json\/wp\/v2\/media?parent=7"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}